• Product Description
    Company Info.
    Model:
    5776080220
    Material:
    Stainless steel
    Connection form:
    Screw thread
    Types:
    Pilot-operated type
    Nominal diameter:
    6 mm
    Applicable medium:
    Air
    Flow direction:
    Commutation
    Parts and accessories:
    Valve body
    Use:
    Commutation
    Standard:
    Aluminum plate
    Form:
    Plunger type
    Pressure environment:
    Normal pressure
    Operating temperature:
    Normal temperature
    AVENTICS solenoid valve 5776080220, Shanghai Weimi Electromechanical Equipment Co., Ltd. Main supply products, product pictures in kind shooting, original factory, warranty for one year, a large number of products in stock supply, price concessions Quick quote, Contact: Lei Qing Welcome to purchase!
     

    AVENTICS 2-position 5-way reversing valve, series CD07 5776080220
    CD07-5/2XX-SR-024DC-E-G014
    AVENTICS CD series consists of a variety of slide valves with extremely durable zinc die cast housings. The CD series of electric, pneumatic or mechanical operating elements (rollers, levers, pedals or push rods) make them ideal for harsh applications.
    specification
    operating an electronic
    Rated flow Qn1200 l/min
    Commutation principle 5/2
    Compressed air connection outlet G 1/4
    Low operating pressure-0.95 bar
    High operating pressure 10 bar
    Operating voltage DC24 V
    Voltage deviation DC-10% / +10%
    manual control locking type
    Electrical connection type Multi-pin plug
    Electrical connection size EN 175301-803, Type A
    Number of electrical connection poles 3-pin
    operating element single coil
    Sealing Principle Soft Seal
    forerunner
    Width of pilot valve 30 mm
    Valve structure type Spool valve, positive overlap
    Connection type Tubular connection
    Reset device with spring reset
    Control pressure 3 bar
    High control pressure 10 bar
    Low ambient temperature-25° C
    High ambient temperature 50° C
    Medium temperature minimum-25° C
    Medium temperature maximum 50° C
    characteristic
    rugged design
    Assembly on base plate
    Suitable for harsh temperature ranges
    withstand voltage fluctuation
    ATEX certified models available

    AVENTICS 2-position 5-way reversing valve, series 740-5727400220
    5/2
    Qn = 700 l/min
    Pipe Fitting
    Compressed air connection outlet:  8x1
    Electrical connection: Multi-pin plug, EN 175301-803, Type A
    - 25° C low temperature resistance
    can be assembled into blocks.
    Manual control device: push button type, locking type
    With air spring return
    Leader: Internal
    Reset type with air spring reset 
    Commutation principle 5/2 
    Structure Features Diaphragm type center valve 
    Shell Polyamide, Polyformaldehyde 
    Seal Material Acrylic Gum 
    Standard circuit interface EN 175301-803:2006 
    degree of protection IP65 
    Interface size EN 175301-803, Type A 
    Type Multi-pin plug 
    Rated flow Qn 700 l/min 
    Compressed air connection Population  8x1 
    Compressed air connection outlet  8x1 
    Operating voltage DC 24 V 
    operating an electronic 
    Temperature Resistance- 25° C Low Temperature Resistance 
    Structure Features  Diaphragm type center valve 
    operating an  electronic 
    leading  interior 
    Sealing Principle  Soft Seal 
    Combination principle (locking principle)  Single base plate principle Disc principle 
    ATEX Class G  II 3G3D EEX nA IIB T4 IP65 T125° C X 
    Working pressure range 1,5... 10 bar 
    Low/High Ambient Temperature-25... 50 °C 
    Medium temperature range-25... 50 °C 
    medium  compressed air 
    Particle size max.  50 μm 
    Oil content in compressed air 0... 5 mg/m3 
    Rated flow Qn  See table 
    Standard circuit interface  EN 175301-803:2006 
    Protection class with interface  IP65 
    Reverse polarity protection  Reverse polarity protection 
    Temporary load rate  100% 
    On-time Model  17 ms 
    Close Time Model  24 ms 
    Assembly PRS-wiring board on multi-circuit wiring board  
    ATEX optional: ATEX variants can be built without base valve combinations with ATEX coils. ATEX-Marking: See ATEX-Coil Catalogue.
    Do not exceed the small control pressure, otherwise it will cause faulty circuits and possible valve failure!
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    The oil content of compressed air must remain constant throughout its service life.

    AVENTICS 2-position 5-way reversing valve, series 740-5727455302
    operating element single coil 
    Reset type with air spring reset 
    Commutation principle 5/2 
    Structure Features Diaphragm type center valve 
    Shell Polyamide, Polyformaldehyde 
    Seal Material Acrylic Gum 
    Standard circuit interface EN 175301-803:2006 
    degree of protection IP65 
    Interface size EN 175301-803, Type A 
    Type Multi-pin plug 
    Rated flow Qn 950 l/min 
    Compressed air connection Population  10 x 1 
    Compressed air connection outlet  10x1 
    operating an electronic 
    Temperature Resistance- 25° C Low Temperature Resistance 
    Structure Features  Diaphragm type center valve 
    operating an  electronic 
    leading  interior 
    Sealing Principle  Soft Seal 
    Combination principle (locking principle)  Single base plate principle Disc principle 
    ATEX Class G  II 3G3D EEX nA IIB T4 IP65 T125° C X 
    Working pressure range 1,5... 10 bar 
    Low/High Ambient Temperature-25... 50 °C 
    Medium temperature range-25... 50 °C 
    medium  compressed air 
    Particle size max.  50 μm 
    Oil content in compressed air 0... 5 mg/m3 
    Standard circuit interface  EN 175301-803:2006 
    Protection class with interface  IP65 
    Reverse polarity protection  Reverse polarity protection 
    Temporary load rate  100% 
    On-time Model  17 ms 
    Close Time Model  24 ms 
    Assembly PRS-wiring board on multi-circuit wiring board  
    ATEX optional: ATEX variants can be built without base valve combinations with ATEX coils.
    Do not exceed the small control pressure, otherwise it will cause faulty circuits and possible valve failure!
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    The oil content of compressed air must remain constant throughout its service life.

    AVENTICS 2/4 reversing valve, series 840-5728450620
    operating element single coil 
    Reset type with air spring reset 
    Commutation principle 4/2 
    Structure Features Diaphragm type center valve 
    shell polyoxymethylene 
    Seal Material Acrylic Gum 
    Standard circuit interface EN 175301-803, Type C 
    degree of protection IP65 
    Interface size EN 175301-803, Type C 
    Type Multi-pin plug 
    Rated flow Qn 200 l/min 
    Compressed air connection Population  6x1 
    Compressed air connection outlet  6 
    Operating voltage DC 24 V 
    operating an electronic 
    Structure Features  Diaphragm type center valve 
    operating an  electronic 
    leading  interior 
    Sealing Principle  Soft Seal 
    Working pressure range 1,8... 10 bar 
    Low/High Ambient Temperature-15... 50 °C 
    Medium temperature range-15... 50 °C 
    medium  compressed air 
    Particle size max.  50 μm 
    Oil content in compressed air 0... 1 mg/m3 
    Rated flow Qn  200 l/min 
    Standard circuit interface  EN 175301-803, Type C 
    Protection class with interface  IP65 
    Reverse polarity protection  Reverse polarity protection 
    Temporary load rate  100% 
    On-time Model  12 ms 
    Close Time Model  12 ms 
    Assembly PRS-wiring board on multi-circuit wiring board  
    Voltage less than 50 V DC without protective contacts.
    High operating pressure depends on ambient temperature. The following values apply:- 15 C... 60 °C : 1.5 bar ... 8 bar Operable working pressure.:- 15 °C ... 40 °C : 1.5 bar ... 10 bar Operable working pressure.
    Do not exceed the small control pressure, otherwise it will result in faulty circuits and possible valve failure!
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    The oil content of compressed air must remain constant throughout its service life.


    AVENTICS Filters-Pressure Regulators, Series AS2-FRE-R412006200
    Components Filters-Pressure Regulators 
    Condensate removal semi-automatic, pressure loss open 
    Secondary exhaust with secondary exhaust 
    Filter pore diameter 5μ m 
    Pressure gauge with pressure gauge 
    lockdown 
    Shell polyamide 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 2100 l/min 
    Compressed air connection G 1/4 
    Structural features  A whole, can be assembled into blocks 
    Components  Filters-Pressure Regulators 
    Installation Position  Vertical 
    Certificate of Conformity  ATEX Fit 
    Low/High Ambient Temperature-10... 50 °C
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Regulator Model  Diaphragm Pressure Regulator 
    Adjustment function  with secondary exhaust 
    pressure transfer  single 
    Water collecting cup volume of filter  28 cm3 
    Filter  element replaceable 
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Please note: Polycarbonate containers are susceptible to solvent attack
    Suitable for use in Ex zones 1, 2, 21 and 22
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
    Due to the structural principle, it is also applicable to the separation of liquid oil or water.& nbsp;
    Large compressed air class 6 : 7 : -according to ISO 8573-1:2010  

    AVENTICS Filters-Pressure Regulators, Series AS2-FRE-R412006221
    Components Filters-Pressure Regulators 
    Condensate removal semi-automatic, pressure loss open 
    Secondary exhaust with secondary exhaust 
    Filter pore diameter 25μ m 
    lockdown 
    Shell polyamide 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 2600 l/min 
    Compressed air connection G 3/8 
    Structural features  A whole, can be assembled into blocks 
    Components  Filters-Pressure Regulators 
    Installation Position  Vertical 
    Certificate of Conformity  ATEX Fit 
    Low/High Ambient Temperature-10... 50 °C
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Regulator Model  Diaphragm Pressure Regulator 
    Adjustment function  with secondary exhaust 
    pressure transfer  single 
    Water collecting cup volume of filter  28 cm3 
    Filter  element replaceable 
    Large compressed air class 7 : 7 : -according to ISO 8573-1:2010  
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Please note: Polycarbonate containers are susceptible to solvent attack
    Suitable for use in Ex zones 1, 2, 21 and 22
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
    Due to the structural principle, it is also applicable to the separation of liquid oil or water.

    AVENTICS Filters-Pressure Regulators, Series AS3-FRE-R412007185
    Components Filters-Pressure Regulators 
    Condensate removal Fully automatic, pressure-free opening 
    Secondary exhaust with secondary exhaust 
    Filter pore diameter 5μ m 
    lockdown 
    Shell polyamide 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 5100 l/min 
    Compressed air connection G 1/2 
    Structural features  A whole, can be assembled into blocks 
    Components  Filters-Pressure Regulators 
    Installation Position  Vertical 
    Certificate of Conformity  ATEX Fit 
    Low/High Ambient Temperature-10... 50 °C
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Rated flow Qn  5100 l/min 
    Regulator Model  Diaphragm Pressure Regulator 
    Adjustment function  with secondary exhaust 
    pressure transfer  single 
    Water collecting cup volume of filter  49 cm3 
    Filter  element replaceable 
    Large compressed air class 6 : 7 : -according to ISO 8573-1:2010  
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Please note: Polycarbonate containers are susceptible to solvent attack
    Suitable for use in Ex zones 1, 2, 21 and 22
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
    Due to the structural principle, it is also applicable to the separation of liquid oil or water.

    AVENTICS Filters-Pressure Regulators, Series AS3-FRE-R412007208
    Components Filters-Pressure Regulators 
    Condensate removal fully automatic, pressure-free shutdown 
    Secondary exhaust with secondary exhaust 
    Filter pore diameter 5μ m 
    Pressure gauge with pressure gauge 
    see-through glass with visible glass 
    lockdown 
    Shell polyamide 
    Air Cup Die Casting Zinc 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 5100 l/min 
    Compressed air connection G 3/8 
    Structural features  A whole, can be assembled into blocks 
    Components  Filters-Pressure Regulators 
    Installation Position  Vertical 
    Certificate of Conformity  ATEX Fit 
    Low/High Ambient Temperature-10... 50 °C
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Rated flow Qn  5100 l/min 
    Regulator Model  Diaphragm Pressure Regulator 
    Adjustment function  with secondary exhaust 
    pressure transfer  single 
    Water collecting cup volume of filter  49 cm3 
    Filter  element replaceable 
    Large compressed air class 6 : 7 : -according to ISO 8573-1:2010  
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Please note: Polycarbonate containers are susceptible to solvent attack
    Suitable for use in Ex zones 1, 2, 21 and 22
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
    Due to the structural principle, it is also applicable to the separation of liquid oil or water.

    AVENTICS Filters-Pressure Regulators, Series AS3-FRE-R412007210
    Components Filters-Pressure Regulators 
    Condensate removal Fully automatic, pressure-free opening 
    Secondary exhaust with secondary exhaust 
    Filter pore diameter 5μ m 
    Pressure gauge with pressure gauge 
    lockdown 
    Shell polyamide 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 5100 l/min 
    Compressed air connection G 1/2 
    Structural features  A whole, can be assembled into blocks 
    Components  Filters-Pressure Regulators 
    Installation Position  Vertical 
    Certificate of Conformity  ATEX Fit 
    Low/High Ambient Temperature-10... 50 °C
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Rated flow Qn  5100 l/min 
    Regulator Model  Diaphragm Pressure Regulator 
    Adjustment function  with secondary exhaust 
    pressure transfer  single 
    Water collecting cup volume of filter  49 cm3 
    Filter  element replaceable 
    Large compressed air class 6 : 7 : -according to ISO 8573-1:2010  
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Please note that polycarbonate containers are susceptible to solvent attack and
    Suitable for use in Ex zones 1, 2, 21 and 22
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
    Due to the structural principle, it is also applicable to the separation of liquid oil or water.& nbsp;

    AVENTICS Standard-Spray Lubricator, Series AS3-LBS-R412007231
    Component Standard-Spray Lubricator 
    Refueling mode Semi-automatic refueling during operation, manual refueling 
    Protective cover with protective cup 
    Shell polyamide 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 8000 l/min 
    Compressed air connection G 1/2 
    Features  Oil mist lubricator, can be assembled into blocks 
    Component  Standard-Spray Lubricator 
    Installation Position  Vertical 
    Certificate of Conformity  ATEX Fit 
    Working pressure range 0,5... 16 bar 
    Low/High Ambient Temperature-10... 50 °C 
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    The water collecting cup of the grease remover has a volume of  80 cm3 
    Refueling mode  Semi-automatic refueling during operation Manual refueling 
    The refueling rate is 1-2 drops per minute at 1000 liters  
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Electronic level monitoring can only be carried out with sensor type ST6 with reed contacts and is supplied with sensor holder.
    Sensors are not included in the scope of supply and are ready for installation.
    The entire set drip volume enters the pressure system
    At high operating pressures of 10 bar, oil can be filled manually during operation.
    Suitable for use in Ex zones 1, 2, 21 and 22
    Please note: Polycarbonate containers are susceptible to solvent attack
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.

    AVENTICS 2-position 3-way shut-off valve, mechanically operated, series AS2-BAV-R412006256
    lockdown 
    Structure characteristics poppet valve 
     tubular tip 
    Shell polyamide 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Qn 1-2 2000 l/min  
    Qn 2-3 380 l/min  
    Compressed air connection Population G 1/4 
    Compressed air connection outlet G 1/4 
    Compressed air connection model Female thread 
    operating mechanical 
    Structure characteristics  poppet valve 
    operating  mechanical 
    closed type  locked type 
    tubular  end of operating element 
    Sealing Principle  Soft Seal 
    Certificate of Conformity  ATEX Fit 
    Working pressure range 0... 16 bar
    Low/High Ambient Temperature-10... 50 °C
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Particle size max.  25 μm 
    Weight  0,206 kg 
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    A small silencer must be included when installing the wall (see accessories section, e.g. R412004817).
    Suitable for use in Ex zones 1, 2, 21 and 22

    AVENTICS 2-position 3-way shut-off valve, mechanically operated, Series AS2-BAV-R412006257
    lockdown 
    Structure characteristics poppet valve 
     tubular tip 
    Shell polyamide 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Qn 1-2 2000 l/min  
    Qn 2-3 380 l/min  
    Compressed air connection Population G 3/8 
    Compressed air connection outlet G 3/8 
    Compressed air connection model Female thread 
    operating mechanical 
    Structure characteristics  poppet valve 
    operating  mechanical 
    closed type  locked type 
    tubular  end of operating element 
    Sealing Principle  Soft Seal 
    Certificate of Conformity  ATEX Fit 
    Working pressure range 0... 16 bar
    Low/High Ambient Temperature-10... 50 °C
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Particle size max.  25 μm 
    Weight  0,206 kg 
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    A small silencer must be included when installing the wall (see accessories section, e.g. R412004817).
    Suitable for use in Ex zones 1, 2, 21 and 22

    AVENTICS 2-position 3-way globe valve, mechanically operated, series AS2-BAV-R412006261
    lockdown 
    Structure characteristics poppet valve 
     tubular tip 
    Shell polyamide 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Qn 1-2 2000 l/min  
    Qn 2-3 380 l/min  
    Compressed air connection Population G 3/8 
    Compressed air connection outlet G 3/8 
    Compressed air connection type Female thread 
    operating mechanical 
    Structure characteristics  poppet valve 
    operating  mechanical 
    closed type  locked type 
    tubular  end of operating element 
    Sealing Principle  Soft Seal 
    Certificate of Conformity  ATEX Fit 
    Working pressure range 0... 16 bar
    Low/High Ambient Temperature-10... 50 °C
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Particle size max.  25 μm 
    Weight  0,206 kg 
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    A small silencer must be included when installing the wall (see accessories section, e.g. R412004817).
    Suitable for use in Ex zones 1, 2, 21 and 22


    AVENTICS 2-position 3-way reversing valve, electrically operated, series AS2-SOV-R412006269
    Structure characteristics poppet valve 
    Shell polyamide 
    Seal Material Acrylic Gum 
    Standard circuit interface ISO 15217 
    degree of protection IP65 
    Interface size ISO 15217, Type C 
    Type Multi-pin plug 
    Qn 1-2 2000 l/min  
    Qn 2-3 380 l/min  
    Rated flow Qn 2000 l/min 
    Compressed air connection Population G 3/8 
    Compressed air connection outlet G 3/8 
    Operating voltage DC 24 V 
    Poppet  valve, can be assembled into blocks 
    2 /3 reversing valve, electrically operated 
    Rated flow 1-2  2000 l/min 
    Rated flow 2-3  380 l/min 
    Operating Pressure Range  See table 
    Medium  Compressed air Neutral gas 
    Medium temperature range-10... 50 °C 
    Low/High Ambient Temperature-10... 50 °C 
    Sealing Principle  Soft Seal 
    Particle size max.  25 μm 
    Degree of protection (safety class) according to DIN EN 61140 with plug  See table 
    Weight  0,219 kg 
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    ATEX Optional: ATEX logo depends on the pilot valve selected.
    A small silencer must be included when installing the wall (see accessories section, e.g. R412004817).

    AVENTICS 2-position 3-way shut-off valve, mechanically operated, series AS3-BAV-R412007261
    lockdown 
    Ball valve 
     tubular tip 
    Shell polyamide 
    Seal Material PTFE 
     Suitable for ATEX 
    Qn 1-2 11000 l/min  
    Qn 2-3 130 l/min  
    Compressed air connection Population G 1/2 
    Compressed air connection outlet G 1/2 
    Compressed air connection type Female thread 
    operating mechanical 
    Ball  valve 
    operating  mechanical 
    closed type  locked type 
    tubular  end of operating element 
    Sealing principle  Metal seal 
    Certificate of Conformity  ATEX Fit 
    Working pressure range 0... 16 bar
    Low/High Ambient Temperature-10... 50 °C
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Particle size max.  25 μm 
    Weight  0,446 kg 
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Suitable for use in Ex zones 1, 2, 21 and 22
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.

    AVENTICS 2-position 3-way reversing valve, electrically operated, series AS3-SOV-R412007269
    Structure characteristics poppet valve 
    Shell polyamide 
    Seal Material Acrylic Gum 
    Standard circuit interface ISO 15217 
    degree of protection IP65 
    Interface size ISO 15217, Type C 
    Type Multi-pin plug 
    Qn 1-2 4500 l/min  
    Qn 2-3 3200 l/min  
    Rated flow Qn 4500 l/min 
    Compressed air connection Population G 1/2 
    Compressed air connection outlet G 1/2 
    Operating voltage DC 24 V 
    Poppet  valve, can be assembled into blocks 
    2 /3 reversing valve, electrically operated 
    Rated flow  4500 l/min 
    Rated flow 1-2  4500 l/min 
    Rated flow 2-3  3200 l/min 
    Medium  Compressed air Neutral gas 
    Medium temperature range-10... 50 °C
    Low/High Ambient Temperature-10... 50 °C 
    Sealing Principle  Soft Seal 
    Particle size max.  25 μm 
    Degree of protection (safety class) according to DIN EN 61140 with plug  IP65 
    Weight  0,459 kg 
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    ATEX Optional: ATEX logo depends on the pilot valve selected.
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.

    AVENTICS Standard-Spray Lubricator, Series NL4-LBS-0821301501
    Component Standard-Spray Lubricator 
    refueling mode manual refueling 
    Protective cover with protective cup 
    Housing Die-cast Zinc 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 6000 l/min 
    Compressed air connection G 1/2 
    Features  Oil mist lubricator, can be assembled into blocks 
    Component  Standard-Spray Lubricator 
    Installation Position  Vertical 
    Working pressure range 0,5... 16 bar
    Low/High Ambient Temperature-10... 60 °C
    Medium temperature range-10... 60 °C 
    Medium  Compressed air Neutral gas 
    refueling mode  manual refueling 
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    The entire set drip volume enters the pressure system
    Manual oil filling during operation
    Please note: Polycarbonate containers are susceptible to solvent attack and can be used in.
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.& nbsp;


    AVENTICS Standard-Spray Lubricator, Series NL4-LBS-0821301500
    Component Standard-Spray Lubricator 
    refueling mode manual refueling 
    Housing Die-cast Zinc 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 6000 l/min 
    Compressed air connection G 1/2 
    Features  Oil mist lubricator, can be assembled into blocks 
    Component  Standard-Spray Lubricator 
    Installation Position  Vertical 
    Working pressure range 0,5... 16 bar
    Low/High Ambient Temperature-10... 60 °C
    Medium temperature range-10... 60 °C 
    Medium  Compressed air Neutral gas 
    refueling mode  manual refueling 
    The refueling rate is 1-2 drops per minute at 1000 liters  
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    The entire set drip volume enters the pressure system
    Manual oil filling during operation
    Please note: Polycarbonate containers are susceptible to solvent attack
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.& nbsp;

    AVENTICS Filters, Series AS2-FLS-R412006002
    Component filters 
    Condensate removal fully automatic, pressure-free shutdown 
    Filter pore diameter 5μ m 
    Shell polyamide 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 2100 l/min 
    Compressed air connection G 1/4 
    Features  Standard filter, can be assembled into blocks 
    Component  filters 
    Installation Position  Vertical 
    Certificate of Conformity  ATEX Fit 
    Low/High Ambient Temperature-10... 50 °C 
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Water collecting cup volume of filter  28 cm3 
    Filter  element replaceable 
    Filter pore diameter  5μ m 
    Large compressed air class 6 : 7 : -according to ISO 8573-1:2010  
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Please note: Polycarbonate containers are susceptible to solvent attack
    Suitable for use in Ex zones 1, 2, 21 and 22
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
    Due to the structural principle, it is also applicable to the separation of liquid oil or water.

    AVENTICS Prefilter, Series AS2-FLP-R412006019
    Components Pre-filter 
    Condensate removal Fully automatic, pressure-free opening 
    Filter pore diameter 0.3μ m 
    Shell polyamide 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 400 l/min 
    Compressed air connection G 1/4 
    Structural features  Pre-filter, can be assembled into blocks 
    Components  Pre-filter 
    Installation Position  Vertical 
    Certificate of Conformity  ATEX Fit 
    Low/High Ambient Temperature-10... 50 °C 
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Water collecting cup volume of filter  12 cm3 
    Filter  element replaceable 
    Filter pore diameter  0,3μ m 
    Recommended primary filtration  5μ m 
    Large compressed air class according to ISO 8573-1:2010  2 : - : 3 
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Please note: Polycarbonate containers are susceptible to solvent attack
    Suitable for use in Ex zones 1, 2, 21 and 22
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
    Due to the structural principle, it is also applicable to the separation of liquid oil or water.

    AVENTICS Filters-Pressure Regulators, Series AS2-FRE-R412006201
    Components Filters-Pressure Regulators 
    Condensate removal Fully automatic, pressure-free opening 
    Secondary exhaust with secondary exhaust 
    Filter pore diameter 5μ m 
    Pressure gauge with pressure gauge 
    lockdown 
    Shell polyamide 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 2100 l/min 
    Compressed air connection G 1/4 
    Structural features  A whole, can be assembled into blocks 
    Components  Filters-Pressure Regulators 
    Installation Position  Vertical 
    Certificate of Conformity  ATEX Fit 
    Low/High Ambient Temperature-10... 50 °C 
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Regulator Model  Diaphragm Pressure Regulator 
    Adjustment function  with secondary exhaust 
    pressure transfer  single 
    Water collecting cup volume of filter  28 cm3 
    Filter  element replaceable 
    Large compressed air class 6 : 7 : -according to ISO 8573-1:2010  
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Please note: Polycarbonate containers are susceptible to solvent attack
    Suitable for use in Ex zones 1, 2, 21 and 22
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
    Due to the structural principle, it is also applicable to the separation of liquid oil or water.


    AVENTICS Filters-Pressure Regulators, Series AS2-FRE-R412006210
    Components Filters-Pressure Regulators 
    Condensate removal Fully automatic, pressure-free opening 
    Secondary exhaust with secondary exhaust 
    Filter pore diameter 5μ m 
    Pressure gauge with pressure gauge 
    lockdown 
    Shell polyamide 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 2600 l/min 
    Compressed air connection G 3/8 
    Structural features  A whole, can be assembled into blocks 
    Components  Filters-Pressure Regulators 
    Installation Position  Vertical 
    Certificate of Conformity  ATEX Fit 
    Low/High Ambient Temperature-10... 50 °C 
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Regulator Model  Diaphragm Pressure Regulator 
    Adjustment function  with secondary exhaust 
    pressure transfer  single 
    Water collecting cup volume of filter  28 cm3 
    Filter  element replaceable 
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Please note: Polycarbonate containers are susceptible to solvent attack
    Suitable for use in Ex zones 1, 2, 21 and 22
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
    Due to the structural principle, it is also applicable to the separation of liquid oil or water.


    AVENTICS Filters-Pressure Regulators, Series AS2-FRE-R412006176
    Components Filters-Pressure Regulators 
    Condensate removal Fully automatic, pressure-free opening 
    Secondary exhaust with secondary exhaust 
    Filter pore diameter 5μ m 
    lockdown 
    Shell polyamide 
    Air Cup Polycarbonate 
    Seal Material Acrylic Gum 
     Suitable for ATEX 
    Rated flow Qn 2100 l/min 
    Compressed air connection G 1/4 
    Structural features  A whole, can be assembled into blocks 
    Components  Filters-Pressure Regulators 
    Installation Position  Vertical 
    Certificate of Conformity  ATEX Fit 
    Low/High Ambient Temperature-10... 50 °C 
    Medium temperature range-10... 50 °C 
    Medium  Compressed air Neutral gas 
    Regulator Model  Diaphragm Pressure Regulator 
    Adjustment function  with secondary exhaust 
    pressure transfer  single 
    Water collecting cup volume of filter  28 cm3 
    Filter  element replaceable 
    The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
    Please note: Polycarbonate containers are susceptible to solvent attack
    Suitable for use in Ex zones 1, 2, 21 and 22
    The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
    Due to the structural principle, it is also applicable to the separation of liquid oil or water.
    Germany AVENTICS solenoid valve 5776080220
    Name(chinese)
    上海韦米机电设备有限公司
    Name(English)
    Shanghai Weimi Mechanical and Electrical Equipment Co., Ltd.
    China credit code
    91310117080035675A Identity Verification
    Registered Capital
    5,000,000 CNY
    Operating term
    2013-10-11 ~ 2033-10-10
    Product Category
    Bosch REXROTH Hydraulic ComponentsAVENTICS Pneumatic Components
    Company Registered Address:
    Room 1017, Building 2, Yuzhou Jinqiao International Phase 2, No. 100 Jinyu Road, Pudong New District, Shanghai City
    Address
    Shanghai Pudong New District, China
    Nearby port
    Shanghai
    Shanghai Weimi Electromechanical Equipment Co., Ltd. is located in Jinqiao Yuzhou International, Pudong New District, Shanghai City. It is a trading company engaged in the management of foreign imported hydraulic and pneumatic spare parts and automated instruments; focusing on the field of industrial transmission automation fluids in China. The company adheres to the concept of integrity and service-oriented. Resolutely safeguard the interests of customers, protect the original products of our brands, provide customers with preferential prices, high-quality products and after-sales sales, achieve win-win cooperation, and create a good trade partnership. Our main products are solenoid valves, proportional valves, plunger pumps, pressure relays, pressure sensors, servo drivers, servo motors, programmable controllers, PLC modules, I/O modules, sensors, cylinders, pneumatic valves, compressed air processing units, industrial instruments, etc. The operating brands include: Bosch Rexroth, AVENTICS, Atos ATOS, Dipma DuploMATIC, B&R, Bentley Bently, Airtec Airtec, Seg ASCO, MooG, PARKER Parker, EATON VICKERS Eaton Vickers, Siemens and other imported brands. We sincerely welcome friends from all walks of life to call us for consultation, on-site inspection and business negotiation.
    Name(chinese)
    上海韦米机电设备有限公司
    Name(English)
    Shanghai Weimi Mechanical and Electrical Equipment Co., Ltd.
    China credit code
    91310117080035675A Identity Verification
    Registered Capital
    5,000,000 CNY
    Operating term
    2013-10-11 ~ 2033-10-10
    Product Category
    Bosch REXROTH Hydraulic ComponentsAVENTICS Pneumatic Components
    Company Registered Address:
    Room 1017, Building 2, Yuzhou Jinqiao International Phase 2, No. 100 Jinyu Road, Pudong New District, Shanghai City
    Address
    Shanghai Pudong New District, China
    Nearby port
    Shanghai
    Shanghai Weimi Electromechanical Equipment Co., Ltd. is located in Jinqiao Yuzhou International, Pudong New District, Shanghai City. It is a trading company engaged in the management of foreign imported hydraulic and pneumatic spare parts and automated instruments; focusing on the field of industrial transmission automation fluids in China. The company adheres to the concept of integrity and service-oriented. Resolutely safeguard the interests of customers, protect the original products of our brands, provide customers with preferential prices, high-quality products and after-sales sales, achieve win-win cooperation, and create a good trade partnership. Our main products are solenoid valves, proportional valves, plunger pumps, pressure relays, pressure sensors, servo drivers, servo motors, programmable controllers, PLC modules, I/O modules, sensors, cylinders, pneumatic valves, compressed air processing units, industrial instruments, etc. The operating brands include: Bosch Rexroth, AVENTICS, Atos ATOS, Dipma DuploMATIC, B&R, Bentley Bently, Airtec Airtec, Seg ASCO, MooG, PARKER Parker, EATON VICKERS Eaton Vickers, Siemens and other imported brands. We sincerely welcome friends from all walks of life to call us for consultation, on-site inspection and business negotiation.
  • Send your message to this supplier
    *From:
    *To:
    Mr. Lei Qing
    *Message:

Copyright © 2003 - 2025 Goepe.com All rights reserved.

浙公网安备 33011802000480号