AVENTICS solenoid valve 5776080220, Shanghai Weimi Electromechanical Equipment Co., Ltd. Main supply products, product pictures in kind shooting, original factory, warranty for one year, a large number of products in stock supply, price concessions Quick quote, Contact: Lei Qing Welcome to purchase!
AVENTICS 2-position 5-way reversing valve, series CD07 5776080220
CD07-5/2XX-SR-024DC-E-G014
AVENTICS CD series consists of a variety of slide valves with extremely durable zinc die cast housings. The CD series of electric, pneumatic or mechanical operating elements (rollers, levers, pedals or push rods) make them ideal for harsh applications.
specification
operating an electronic
Rated flow Qn1200 l/min
Commutation principle 5/2
Compressed air connection outlet G 1/4
Low operating pressure-0.95 bar
High operating pressure 10 bar
Operating voltage DC24 V
Voltage deviation DC-10% / +10%
manual control locking type
Electrical connection type Multi-pin plug
Electrical connection size EN 175301-803, Type A
Number of electrical connection poles 3-pin
operating element single coil
Sealing Principle Soft Seal
forerunner
Width of pilot valve 30 mm
Valve structure type Spool valve, positive overlap
Connection type Tubular connection
Reset device with spring reset
Control pressure 3 bar
High control pressure 10 bar
Low ambient temperature-25° C
High ambient temperature 50° C
Medium temperature minimum-25° C
Medium temperature maximum 50° C
characteristic
rugged design
Assembly on base plate
Suitable for harsh temperature ranges
withstand voltage fluctuation
ATEX certified models available
AVENTICS 2-position 5-way reversing valve, series 740-5727400220
5/2
Qn = 700 l/min
Pipe Fitting
Compressed air connection outlet: 8x1
Electrical connection: Multi-pin plug, EN 175301-803, Type A
- 25° C low temperature resistance
can be assembled into blocks.
Manual control device: push button type, locking type
With air spring return
Leader: Internal
Reset type with air spring reset
Commutation principle 5/2
Structure Features Diaphragm type center valve
Shell Polyamide, Polyformaldehyde
Seal Material Acrylic Gum
Standard circuit interface EN 175301-803:2006
degree of protection IP65
Interface size EN 175301-803, Type A
Type Multi-pin plug
Rated flow Qn 700 l/min
Compressed air connection Population 8x1
Compressed air connection outlet 8x1
Operating voltage DC 24 V
operating an electronic
Temperature Resistance- 25° C Low Temperature Resistance
Structure Features Diaphragm type center valve
operating an electronic
leading interior
Sealing Principle Soft Seal
Combination principle (locking principle) Single base plate principle Disc principle
ATEX Class G II 3G3D EEX nA IIB T4 IP65 T125° C X
Working pressure range 1,5... 10 bar
Low/High Ambient Temperature-25... 50 °C
Medium temperature range-25... 50 °C
medium compressed air
Particle size max. 50 μm
Oil content in compressed air 0... 5 mg/m3
Rated flow Qn See table
Standard circuit interface EN 175301-803:2006
Protection class with interface IP65
Reverse polarity protection Reverse polarity protection
Temporary load rate 100%
On-time Model 17 ms
Close Time Model 24 ms
Assembly PRS-wiring board on multi-circuit wiring board
ATEX optional: ATEX variants can be built without base valve combinations with ATEX coils. ATEX-Marking: See ATEX-Coil Catalogue.
Do not exceed the small control pressure, otherwise it will cause faulty circuits and possible valve failure!
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
The oil content of compressed air must remain constant throughout its service life.
AVENTICS 2-position 5-way reversing valve, series 740-5727455302
operating element single coil
Reset type with air spring reset
Commutation principle 5/2
Structure Features Diaphragm type center valve
Shell Polyamide, Polyformaldehyde
Seal Material Acrylic Gum
Standard circuit interface EN 175301-803:2006
degree of protection IP65
Interface size EN 175301-803, Type A
Type Multi-pin plug
Rated flow Qn 950 l/min
Compressed air connection Population 10 x 1
Compressed air connection outlet 10x1
operating an electronic
Temperature Resistance- 25° C Low Temperature Resistance
Structure Features Diaphragm type center valve
operating an electronic
leading interior
Sealing Principle Soft Seal
Combination principle (locking principle) Single base plate principle Disc principle
ATEX Class G II 3G3D EEX nA IIB T4 IP65 T125° C X
Working pressure range 1,5... 10 bar
Low/High Ambient Temperature-25... 50 °C
Medium temperature range-25... 50 °C
medium compressed air
Particle size max. 50 μm
Oil content in compressed air 0... 5 mg/m3
Standard circuit interface EN 175301-803:2006
Protection class with interface IP65
Reverse polarity protection Reverse polarity protection
Temporary load rate 100%
On-time Model 17 ms
Close Time Model 24 ms
Assembly PRS-wiring board on multi-circuit wiring board
ATEX optional: ATEX variants can be built without base valve combinations with ATEX coils.
Do not exceed the small control pressure, otherwise it will cause faulty circuits and possible valve failure!
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
The oil content of compressed air must remain constant throughout its service life.
AVENTICS 2/4 reversing valve, series 840-5728450620
operating element single coil
Reset type with air spring reset
Commutation principle 4/2
Structure Features Diaphragm type center valve
shell polyoxymethylene
Seal Material Acrylic Gum
Standard circuit interface EN 175301-803, Type C
degree of protection IP65
Interface size EN 175301-803, Type C
Type Multi-pin plug
Rated flow Qn 200 l/min
Compressed air connection Population 6x1
Compressed air connection outlet 6
Operating voltage DC 24 V
operating an electronic
Structure Features Diaphragm type center valve
operating an electronic
leading interior
Sealing Principle Soft Seal
Working pressure range 1,8... 10 bar
Low/High Ambient Temperature-15... 50 °C
Medium temperature range-15... 50 °C
medium compressed air
Particle size max. 50 μm
Oil content in compressed air 0... 1 mg/m3
Rated flow Qn 200 l/min
Standard circuit interface EN 175301-803, Type C
Protection class with interface IP65
Reverse polarity protection Reverse polarity protection
Temporary load rate 100%
On-time Model 12 ms
Close Time Model 12 ms
Assembly PRS-wiring board on multi-circuit wiring board
Voltage less than 50 V DC without protective contacts.
High operating pressure depends on ambient temperature. The following values apply:- 15 C... 60 °C : 1.5 bar ... 8 bar Operable working pressure.:- 15 °C ... 40 °C : 1.5 bar ... 10 bar Operable working pressure.
Do not exceed the small control pressure, otherwise it will result in faulty circuits and possible valve failure!
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
The oil content of compressed air must remain constant throughout its service life.
AVENTICS Filters-Pressure Regulators, Series AS2-FRE-R412006200
Components Filters-Pressure Regulators
Condensate removal semi-automatic, pressure loss open
Secondary exhaust with secondary exhaust
Filter pore diameter 5μ m
Pressure gauge with pressure gauge
lockdown
Shell polyamide
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 2100 l/min
Compressed air connection G 1/4
Structural features A whole, can be assembled into blocks
Components Filters-Pressure Regulators
Installation Position Vertical
Certificate of Conformity ATEX Fit
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Regulator Model Diaphragm Pressure Regulator
Adjustment function with secondary exhaust
pressure transfer single
Water collecting cup volume of filter 28 cm3
Filter element replaceable
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Please note: Polycarbonate containers are susceptible to solvent attack
Suitable for use in Ex zones 1, 2, 21 and 22
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
Due to the structural principle, it is also applicable to the separation of liquid oil or water.& nbsp;
Large compressed air class 6 : 7 : -according to ISO 8573-1:2010
AVENTICS Filters-Pressure Regulators, Series AS2-FRE-R412006221
Components Filters-Pressure Regulators
Condensate removal semi-automatic, pressure loss open
Secondary exhaust with secondary exhaust
Filter pore diameter 25μ m
lockdown
Shell polyamide
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 2600 l/min
Compressed air connection G 3/8
Structural features A whole, can be assembled into blocks
Components Filters-Pressure Regulators
Installation Position Vertical
Certificate of Conformity ATEX Fit
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Regulator Model Diaphragm Pressure Regulator
Adjustment function with secondary exhaust
pressure transfer single
Water collecting cup volume of filter 28 cm3
Filter element replaceable
Large compressed air class 7 : 7 : -according to ISO 8573-1:2010
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Please note: Polycarbonate containers are susceptible to solvent attack
Suitable for use in Ex zones 1, 2, 21 and 22
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
Due to the structural principle, it is also applicable to the separation of liquid oil or water.
AVENTICS Filters-Pressure Regulators, Series AS3-FRE-R412007185
Components Filters-Pressure Regulators
Condensate removal Fully automatic, pressure-free opening
Secondary exhaust with secondary exhaust
Filter pore diameter 5μ m
lockdown
Shell polyamide
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 5100 l/min
Compressed air connection G 1/2
Structural features A whole, can be assembled into blocks
Components Filters-Pressure Regulators
Installation Position Vertical
Certificate of Conformity ATEX Fit
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Rated flow Qn 5100 l/min
Regulator Model Diaphragm Pressure Regulator
Adjustment function with secondary exhaust
pressure transfer single
Water collecting cup volume of filter 49 cm3
Filter element replaceable
Large compressed air class 6 : 7 : -according to ISO 8573-1:2010
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Please note: Polycarbonate containers are susceptible to solvent attack
Suitable for use in Ex zones 1, 2, 21 and 22
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
Due to the structural principle, it is also applicable to the separation of liquid oil or water.
AVENTICS Filters-Pressure Regulators, Series AS3-FRE-R412007208
Components Filters-Pressure Regulators
Condensate removal fully automatic, pressure-free shutdown
Secondary exhaust with secondary exhaust
Filter pore diameter 5μ m
Pressure gauge with pressure gauge
see-through glass with visible glass
lockdown
Shell polyamide
Air Cup Die Casting Zinc
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 5100 l/min
Compressed air connection G 3/8
Structural features A whole, can be assembled into blocks
Components Filters-Pressure Regulators
Installation Position Vertical
Certificate of Conformity ATEX Fit
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Rated flow Qn 5100 l/min
Regulator Model Diaphragm Pressure Regulator
Adjustment function with secondary exhaust
pressure transfer single
Water collecting cup volume of filter 49 cm3
Filter element replaceable
Large compressed air class 6 : 7 : -according to ISO 8573-1:2010
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Please note: Polycarbonate containers are susceptible to solvent attack
Suitable for use in Ex zones 1, 2, 21 and 22
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
Due to the structural principle, it is also applicable to the separation of liquid oil or water.
AVENTICS Filters-Pressure Regulators, Series AS3-FRE-R412007210
Components Filters-Pressure Regulators
Condensate removal Fully automatic, pressure-free opening
Secondary exhaust with secondary exhaust
Filter pore diameter 5μ m
Pressure gauge with pressure gauge
lockdown
Shell polyamide
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 5100 l/min
Compressed air connection G 1/2
Structural features A whole, can be assembled into blocks
Components Filters-Pressure Regulators
Installation Position Vertical
Certificate of Conformity ATEX Fit
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Rated flow Qn 5100 l/min
Regulator Model Diaphragm Pressure Regulator
Adjustment function with secondary exhaust
pressure transfer single
Water collecting cup volume of filter 49 cm3
Filter element replaceable
Large compressed air class 6 : 7 : -according to ISO 8573-1:2010
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Please note that polycarbonate containers are susceptible to solvent attack and
Suitable for use in Ex zones 1, 2, 21 and 22
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
Due to the structural principle, it is also applicable to the separation of liquid oil or water.& nbsp;
AVENTICS Standard-Spray Lubricator, Series AS3-LBS-R412007231
Component Standard-Spray Lubricator
Refueling mode Semi-automatic refueling during operation, manual refueling
Protective cover with protective cup
Shell polyamide
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 8000 l/min
Compressed air connection G 1/2
Features Oil mist lubricator, can be assembled into blocks
Component Standard-Spray Lubricator
Installation Position Vertical
Certificate of Conformity ATEX Fit
Working pressure range 0,5... 16 bar
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
The water collecting cup of the grease remover has a volume of 80 cm3
Refueling mode Semi-automatic refueling during operation Manual refueling
The refueling rate is 1-2 drops per minute at 1000 liters
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Electronic level monitoring can only be carried out with sensor type ST6 with reed contacts and is supplied with sensor holder.
Sensors are not included in the scope of supply and are ready for installation.
The entire set drip volume enters the pressure system
At high operating pressures of 10 bar, oil can be filled manually during operation.
Suitable for use in Ex zones 1, 2, 21 and 22
Please note: Polycarbonate containers are susceptible to solvent attack
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
AVENTICS 2-position 3-way shut-off valve, mechanically operated, series AS2-BAV-R412006256
lockdown
Structure characteristics poppet valve
tubular tip
Shell polyamide
Seal Material Acrylic Gum
Suitable for ATEX
Qn 1-2 2000 l/min
Qn 2-3 380 l/min
Compressed air connection Population G 1/4
Compressed air connection outlet G 1/4
Compressed air connection model Female thread
operating mechanical
Structure characteristics poppet valve
operating mechanical
closed type locked type
tubular end of operating element
Sealing Principle Soft Seal
Certificate of Conformity ATEX Fit
Working pressure range 0... 16 bar
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Particle size max. 25 μm
Weight 0,206 kg
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
A small silencer must be included when installing the wall (see accessories section, e.g. R412004817).
Suitable for use in Ex zones 1, 2, 21 and 22
AVENTICS 2-position 3-way shut-off valve, mechanically operated, Series AS2-BAV-R412006257
lockdown
Structure characteristics poppet valve
tubular tip
Shell polyamide
Seal Material Acrylic Gum
Suitable for ATEX
Qn 1-2 2000 l/min
Qn 2-3 380 l/min
Compressed air connection Population G 3/8
Compressed air connection outlet G 3/8
Compressed air connection model Female thread
operating mechanical
Structure characteristics poppet valve
operating mechanical
closed type locked type
tubular end of operating element
Sealing Principle Soft Seal
Certificate of Conformity ATEX Fit
Working pressure range 0... 16 bar
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Particle size max. 25 μm
Weight 0,206 kg
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
A small silencer must be included when installing the wall (see accessories section, e.g. R412004817).
Suitable for use in Ex zones 1, 2, 21 and 22
AVENTICS 2-position 3-way globe valve, mechanically operated, series AS2-BAV-R412006261
lockdown
Structure characteristics poppet valve
tubular tip
Shell polyamide
Seal Material Acrylic Gum
Suitable for ATEX
Qn 1-2 2000 l/min
Qn 2-3 380 l/min
Compressed air connection Population G 3/8
Compressed air connection outlet G 3/8
Compressed air connection type Female thread
operating mechanical
Structure characteristics poppet valve
operating mechanical
closed type locked type
tubular end of operating element
Sealing Principle Soft Seal
Certificate of Conformity ATEX Fit
Working pressure range 0... 16 bar
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Particle size max. 25 μm
Weight 0,206 kg
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
A small silencer must be included when installing the wall (see accessories section, e.g. R412004817).
Suitable for use in Ex zones 1, 2, 21 and 22
AVENTICS 2-position 3-way reversing valve, electrically operated, series AS2-SOV-R412006269
Structure characteristics poppet valve
Shell polyamide
Seal Material Acrylic Gum
Standard circuit interface ISO 15217
degree of protection IP65
Interface size ISO 15217, Type C
Type Multi-pin plug
Qn 1-2 2000 l/min
Qn 2-3 380 l/min
Rated flow Qn 2000 l/min
Compressed air connection Population G 3/8
Compressed air connection outlet G 3/8
Operating voltage DC 24 V
Poppet valve, can be assembled into blocks
2 /3 reversing valve, electrically operated
Rated flow 1-2 2000 l/min
Rated flow 2-3 380 l/min
Operating Pressure Range See table
Medium Compressed air Neutral gas
Medium temperature range-10... 50 °C
Low/High Ambient Temperature-10... 50 °C
Sealing Principle Soft Seal
Particle size max. 25 μm
Degree of protection (safety class) according to DIN EN 61140 with plug See table
Weight 0,219 kg
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
ATEX Optional: ATEX logo depends on the pilot valve selected.
A small silencer must be included when installing the wall (see accessories section, e.g. R412004817).
AVENTICS 2-position 3-way shut-off valve, mechanically operated, series AS3-BAV-R412007261
lockdown
Ball valve
tubular tip
Shell polyamide
Seal Material PTFE
Suitable for ATEX
Qn 1-2 11000 l/min
Qn 2-3 130 l/min
Compressed air connection Population G 1/2
Compressed air connection outlet G 1/2
Compressed air connection type Female thread
operating mechanical
Ball valve
operating mechanical
closed type locked type
tubular end of operating element
Sealing principle Metal seal
Certificate of Conformity ATEX Fit
Working pressure range 0... 16 bar
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Particle size max. 25 μm
Weight 0,446 kg
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Suitable for use in Ex zones 1, 2, 21 and 22
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
AVENTICS 2-position 3-way reversing valve, electrically operated, series AS3-SOV-R412007269
Structure characteristics poppet valve
Shell polyamide
Seal Material Acrylic Gum
Standard circuit interface ISO 15217
degree of protection IP65
Interface size ISO 15217, Type C
Type Multi-pin plug
Qn 1-2 4500 l/min
Qn 2-3 3200 l/min
Rated flow Qn 4500 l/min
Compressed air connection Population G 1/2
Compressed air connection outlet G 1/2
Operating voltage DC 24 V
Poppet valve, can be assembled into blocks
2 /3 reversing valve, electrically operated
Rated flow 4500 l/min
Rated flow 1-2 4500 l/min
Rated flow 2-3 3200 l/min
Medium Compressed air Neutral gas
Medium temperature range-10... 50 °C
Low/High Ambient Temperature-10... 50 °C
Sealing Principle Soft Seal
Particle size max. 25 μm
Degree of protection (safety class) according to DIN EN 61140 with plug IP65
Weight 0,459 kg
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
ATEX Optional: ATEX logo depends on the pilot valve selected.
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
AVENTICS Standard-Spray Lubricator, Series NL4-LBS-0821301501
Component Standard-Spray Lubricator
refueling mode manual refueling
Protective cover with protective cup
Housing Die-cast Zinc
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 6000 l/min
Compressed air connection G 1/2
Features Oil mist lubricator, can be assembled into blocks
Component Standard-Spray Lubricator
Installation Position Vertical
Working pressure range 0,5... 16 bar
Low/High Ambient Temperature-10... 60 °C
Medium temperature range-10... 60 °C
Medium Compressed air Neutral gas
refueling mode manual refueling
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
The entire set drip volume enters the pressure system
Manual oil filling during operation
Please note: Polycarbonate containers are susceptible to solvent attack and can be used in.
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.& nbsp;
AVENTICS Standard-Spray Lubricator, Series NL4-LBS-0821301500
Component Standard-Spray Lubricator
refueling mode manual refueling
Housing Die-cast Zinc
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 6000 l/min
Compressed air connection G 1/2
Features Oil mist lubricator, can be assembled into blocks
Component Standard-Spray Lubricator
Installation Position Vertical
Working pressure range 0,5... 16 bar
Low/High Ambient Temperature-10... 60 °C
Medium temperature range-10... 60 °C
Medium Compressed air Neutral gas
refueling mode manual refueling
The refueling rate is 1-2 drops per minute at 1000 liters
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
The entire set drip volume enters the pressure system
Manual oil filling during operation
Please note: Polycarbonate containers are susceptible to solvent attack
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.& nbsp;
AVENTICS Filters, Series AS2-FLS-R412006002
Component filters
Condensate removal fully automatic, pressure-free shutdown
Filter pore diameter 5μ m
Shell polyamide
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 2100 l/min
Compressed air connection G 1/4
Features Standard filter, can be assembled into blocks
Component filters
Installation Position Vertical
Certificate of Conformity ATEX Fit
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Water collecting cup volume of filter 28 cm3
Filter element replaceable
Filter pore diameter 5μ m
Large compressed air class 6 : 7 : -according to ISO 8573-1:2010
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Please note: Polycarbonate containers are susceptible to solvent attack
Suitable for use in Ex zones 1, 2, 21 and 22
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
Due to the structural principle, it is also applicable to the separation of liquid oil or water.
AVENTICS Prefilter, Series AS2-FLP-R412006019
Components Pre-filter
Condensate removal Fully automatic, pressure-free opening
Filter pore diameter 0.3μ m
Shell polyamide
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 400 l/min
Compressed air connection G 1/4
Structural features Pre-filter, can be assembled into blocks
Components Pre-filter
Installation Position Vertical
Certificate of Conformity ATEX Fit
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Water collecting cup volume of filter 12 cm3
Filter element replaceable
Filter pore diameter 0,3μ m
Recommended primary filtration 5μ m
Large compressed air class according to ISO 8573-1:2010 2 : - : 3
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Please note: Polycarbonate containers are susceptible to solvent attack
Suitable for use in Ex zones 1, 2, 21 and 22
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
Due to the structural principle, it is also applicable to the separation of liquid oil or water.
AVENTICS Filters-Pressure Regulators, Series AS2-FRE-R412006201
Components Filters-Pressure Regulators
Condensate removal Fully automatic, pressure-free opening
Secondary exhaust with secondary exhaust
Filter pore diameter 5μ m
Pressure gauge with pressure gauge
lockdown
Shell polyamide
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 2100 l/min
Compressed air connection G 1/4
Structural features A whole, can be assembled into blocks
Components Filters-Pressure Regulators
Installation Position Vertical
Certificate of Conformity ATEX Fit
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Regulator Model Diaphragm Pressure Regulator
Adjustment function with secondary exhaust
pressure transfer single
Water collecting cup volume of filter 28 cm3
Filter element replaceable
Large compressed air class 6 : 7 : -according to ISO 8573-1:2010
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Please note: Polycarbonate containers are susceptible to solvent attack
Suitable for use in Ex zones 1, 2, 21 and 22
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
Due to the structural principle, it is also applicable to the separation of liquid oil or water.
AVENTICS Filters-Pressure Regulators, Series AS2-FRE-R412006210
Components Filters-Pressure Regulators
Condensate removal Fully automatic, pressure-free opening
Secondary exhaust with secondary exhaust
Filter pore diameter 5μ m
Pressure gauge with pressure gauge
lockdown
Shell polyamide
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 2600 l/min
Compressed air connection G 3/8
Structural features A whole, can be assembled into blocks
Components Filters-Pressure Regulators
Installation Position Vertical
Certificate of Conformity ATEX Fit
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Regulator Model Diaphragm Pressure Regulator
Adjustment function with secondary exhaust
pressure transfer single
Water collecting cup volume of filter 28 cm3
Filter element replaceable
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Please note: Polycarbonate containers are susceptible to solvent attack
Suitable for use in Ex zones 1, 2, 21 and 22
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
Due to the structural principle, it is also applicable to the separation of liquid oil or water.
AVENTICS Filters-Pressure Regulators, Series AS2-FRE-R412006176
Components Filters-Pressure Regulators
Condensate removal Fully automatic, pressure-free opening
Secondary exhaust with secondary exhaust
Filter pore diameter 5μ m
lockdown
Shell polyamide
Air Cup Polycarbonate
Seal Material Acrylic Gum
Suitable for ATEX
Rated flow Qn 2100 l/min
Compressed air connection G 1/4
Structural features A whole, can be assembled into blocks
Components Filters-Pressure Regulators
Installation Position Vertical
Certificate of Conformity ATEX Fit
Low/High Ambient Temperature-10... 50 °C
Medium temperature range-10... 50 °C
Medium Compressed air Neutral gas
Regulator Model Diaphragm Pressure Regulator
Adjustment function with secondary exhaust
pressure transfer single
Water collecting cup volume of filter 28 cm3
Filter element replaceable
The pressure must be at least 15 C below ambient and medium temperatures, and the allowable high temperature is 3 C.
Please note: Polycarbonate containers are susceptible to solvent attack
Suitable for use in Ex zones 1, 2, 21 and 22
The change in direction of flow (from air supply to left in air supply to right) is made by means of rotation at 180 ° on the vertical axis. For details, see operating instructions.
Due to the structural principle, it is also applicable to the separation of liquid oil or water.
Germany AVENTICS solenoid valve 5776080220